VCF 9.0 Fleet Latency Diagram

12.11.2025 by William Lam // 2 Comments

Network latency is an important factor when designing a VMware Cloud Foundation (VCF) Fleet and to assist VCF architects in understanding the various latency maximums, we have just published a new VCF Fleet Latency Network Diagram, which is available under the Network Diagrams on the VMware Ports & Protocols website.


While these latency represent the upper bound for component to component functionality, it is also important to understand that latency can have different types of impact based on the type of traffic: control plane (UI/API) versus data plane (binary download/uploads).

For example, most of the UI/API invocations are asynchronous, meaning the requests will be recieved by a component but it may be slow to respond with higher latency. For data plane traffic, throughput is typically reduced and longer transfer times maybe observed with higher latency. Luckily, for Lifecycle management operations, it is fairly common to stage the binaries prior to performing the lifecycle operation, so while transfer times may take longer, we can mitigate any impact of the actual lifecycle operation.

Note:  One thing I would like to point out in the diagram is that VCF Operations Collector expects <=50ms to vCenter Server, NSX Manager and SDDC Manager. In the scenarios where you might have a Workload Domain vCenter Server (Brownfield Import) that is a bit further away from the primary VCF Operations Collector within VCF Instance, we can mitigate that by deploying an additional VCF Operations Collector that is local to that Workload Domain and thus ensuring the <=50ms requirement while benefiting from the <=300ms back to VCF Operations.

As the first version of the VCF Fleet Latency diagram, only the primary VCF components within a VCF Fleet has been included in this initial diagram. Additional VCF components will be incorporated into future iterations based on your feedback. If there are things you would like to see in future updates, you can leave feedback directly on the Broadcom page or feel free to leave a comment below and I will make sure it reaches the PM.

Categories // VMware Cloud Foundation Tags // VCF 9.0

Comments

  1. *protectedJefferson says

    12/11/2025 at 1:40 pm

    Can we get NSX LM NSX GM, NSX GM NSX GM, and NSX LM NSX LM latencies added to that chart? (Somehow it should show the differences between stretched segment latency limits and security only latency limits.) I know where to look them up, but it would be helpful to have all of these in one spot.

    Reply
  2. *protectedMarcel Mertens says

    12/12/2025 at 3:02 am

    Thank you William, this is very helpful! The documentation is some kind of incomplete or not accurate enough for some design pattern.
    Do I understand this correct, that i can have my 1st VCF Instance in with Ops/Automation and additional VCF Instances within 300ms of latency (US/ASIA) to the 1st VCF Instance MGMT Domain.

    Reply

Thanks for the comment!Cancel reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Search

Thank Author

Author

William is Distinguished Platform Engineering Architect in the VMware Cloud Foundation (VCF) Division at Broadcom. His primary focus is helping customers and partners build, run and operate a modern Private Cloud using the VMware Cloud Foundation (VCF) platform.

Connect

  • Bluesky
  • Email
  • GitHub
  • LinkedIn
  • Mastodon
  • Reddit
  • RSS
  • Twitter
  • Vimeo

Recent

  • Quick Tip - NSX Edge fails DNS pre-check as part of VCF 9.0.2 Upgrade 01/23/2026
  • Quick Tip - No space left on device when upgrading VCF Operations using VCF Operations Fleet Manager to VCF 9.0.2 01/22/2026
  • Every Mini PC & SFF Hardware Announced at CES 2026 01/21/2026
  • Improved Workaround for NSX Edge Deployment & Upgrade to VCF 9.0.2 running AMD Ryzen CPUs 01/20/2026
  • Disable HTTP Range Requests on Synology WebStation, Apache or Nginx 01/14/2026

Advertisment

Privacy & Cookies: This site uses cookies. By continuing to use this website, you agree to their use.

To find out more, including how to control cookies, see here: Cookie Policy

Copyright WilliamLam.com © 2026

 

Loading Comments...