Handy VSAN VOBs for creating vCenter Alarms

04.22.2014 by William Lam // 3 Comments

There have been quite a few questions lately around vCenter Server Alarms for VSAN, one in particular that I have noticed is around individual disk failure for VSAN. Outside of the generic default datastore alarms, there seems to be only two VSAN specific alarms:

vsan-default-alarms
I figure there must be other useful alarms that we could create, especially after showing how you can create a vCenter Server Alarm to monitor the VSAN component count threshold based on a particular VSAN VOB. I took a look around and found the following VSAN specific VOBs which could be useful for creating additional vCenter Alarms.

VOB ID VOB Description
esx.audit.vsan.clustering.enabled VSAN clustering services have been enabled.
esx.clear.vob.vsan.pdl.online VSAN device has come online.
esx.clear.vsan.clustering.enabled VSAN clustering services have now been enabled.
esx.clear.vsan.vsan.network.available VSAN now has at least one active network configuration.
esx.clear.vsan.vsan.vmknic.ready A previously reported vmknic now has a valid IP.
esx.problem.vob.vsan.lsom.componentthreshold VSAN Node: Near node component count limit.
esx.problem.vob.vsan.lsom.diskerror VSAN device is under permanent error.
esx.problem.vob.vsan.lsom.diskgrouplimit Failed to create a new disk group.
esx.problem.vob.vsan.lsom.disklimit Failed to add disk to disk group.
esx.problem.vob.vsan.pdl.offline VSAN device has gone offline.
esx.problem.vsan.clustering.disabled VSAN clustering services have been disabled.
esx.problem.vsan.lsom.congestionthreshold VSAN device Memory/SSD congestion has changed.
esx.problem.vsan.net.not.ready A vmknic added to VSAN network configuration doesn't have valid IP. Network is not ready.
esx.problem.vsan.net.redundancy.lost VSAN doesn't haven any redundancy in its network configuration.
esx.problem.vsan.net.redundancy.reduced VSAN is operating on reduced network redundancy.
esx.problem.vsan.no.network.connectivity VSAN doesn't have any networking configuration for use.
esx.problem.vsan.vmknic.not.ready A vmknic added to VSAN network configuration doesn't have valid IP. It will not be in use.

Looking at the list above, the following two VOBs seems like they would be useful for alerting on a disk failure is:

  • esx.problem.vob.vsan.lsom.diskerror
  • esx.problem.vob.vsan.pdl.offline

Disclaimer: There are no guarantees that a disk error or failure will automatically trigger these VOBs due to the unknown nature of how a disk may be fail, especially if it is intermittently.

Even though we can not simulate a disk error on a physical disk, we can still do some magic using a Nested VSAN environment. The worse case scenario that you could run into is that one of the disk just goes completely offline. We can simulate a similar behavior in a Nested ESXi environment by removing one of the virtual disks from the Virtual Machine (not deleting it).

To demonstrate the following scenario, here are the steps to create a vCenter Alarm for the following two VOBs:

Step 1 - Create a new vCenter Alarm and give it a name. Select “Hosts” for Monitor and “Specific event occurring …” for Monitor:

vsan-disk-failure-alarm-0
Step 2 - Add the following two VOBs above into the Event trigger:

vsan-disk-failure-alarm-1
Step 3 - Remove one of the Virtual Disks (SSD/MD) from the Virtual Machine running the Nested ESXi VM.

Step 4 - There are two ways in which you can trigger the alarm. You can either create a new Virtual Machine which will try to write to the Nested ESXi VM in which you remove the Virtual Disk or you can rescan the storage adapter for the Nested ESXi VM. In my environment, I happen to have a VM running on an NFS datastore and I performed a Storage vMotion of the VM onto my VSAN Datastore using the default FTT=1 policy on a three node VSAN Cluster. This immediately triggered the alarm as seen in the screenshots below:

vsan-disk-failure-alarm-2

vsan-disk-failure-alarm-3

More from my site

  • How to automatically monitor VSAN Component threshold using a vCenter Alarm?
  • New VOBs for creating vCenter Server alarms in vSphere 6.0
  • A killer custom Apple Mac Mini setup running VSAN
  • Does VSAN work with Free ESXi?
  • ESXi 5.5 Kickstart script for setting up VSAN

Categories // VSAN, vSphere 5.5 Tags // alarm, ESXi 5.5, vob, VSAN, vSphere 5.5

Comments

  1. *protectedJarek says

    04/14/2015 at 7:40 am

    Great stuff!

    Do you know if is possible to define "New Alarm" with "VirtualMachine.Config.AddNewDisk" only when using VM-Reconfigured?
    That will only alarm when new disk was added/created?

    Regards,
    Jarek

    Reply
    • William Lam says

      04/14/2015 at 3:55 pm

      Correction, for changes to a VM, you'll just get the generic "VmReconfiguredEvent" event. However, within the event there is a configSpec that would give you exactly what changed. It's not pretty and you would need to do some parsing, but it is possible. In fact, here's a nice solution from fellow Automation community member Luc Dekens on a PowerCLI script that does this http://www.lucd.info/2009/12/18/events-part-3-auditing-vm-device-changes/

      Reply
      • *protectedJarek says

        04/16/2015 at 7:12 am

        Hi,

        Thx for swift reply 🙂
        I will check the link, and will try to figure it out how to get configSpec within the alarm

        Regards,
        Jarek

        Reply

Leave a Reply to William LamCancel reply

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Search

Thank Author

Author

William is Distinguished Platform Engineering Architect in the VMware Cloud Foundation (VCF) Division at Broadcom. His primary focus is helping customers and partners build, run and operate a modern Private Cloud using the VMware Cloud Foundation (VCF) platform.

Connect

  • Bluesky
  • Email
  • GitHub
  • LinkedIn
  • Mastodon
  • Reddit
  • RSS
  • Twitter
  • Vimeo

Recent

  • Programmatically accessing the Broadcom Compatibility Guide (BCG) 05/06/2025
  • Quick Tip - Validating Broadcom Download Token  05/01/2025
  • Supported chipsets for the USB Network Native Driver for ESXi Fling 04/23/2025
  • vCenter Identity Federation with Authelia 04/16/2025
  • vCenter Server Identity Federation with Kanidm 04/10/2025

Advertisment

Privacy & Cookies: This site uses cookies. By continuing to use this website, you agree to their use.
To find out more, including how to control cookies, see here: Cookie Policy

Copyright WilliamLam.com © 2025

 

Loading Comments...